# Deployment Method Selection Guide

> Choose a Stellar Cyber OpenXDR deployment model based on infrastructure, performance needs, and operational constraints.

# Deployment Method Selection Guide

![OpenXDR KVM Installer requirements-based deployment guide](https://mintcdn.com/kvm-installer/MaTPwLZIA7IYvA65/images/KVM-Installer/1.png?fit=max\&auto=format\&n=MaTPwLZIA7IYvA65\&q=85\&s=b87fcec6fd8df80593481e511040adbf)

## Overview

This guide compares deployment models for the **Stellar Cyber OpenXDR Platform** based on infrastructure, performance needs, and operational constraints.

Rather than focusing on the installer's internal implementation, it is intended to help operators decide:

* which installer to use
* which network mode or attachment method to select
* how to balance performance, stability, and day-to-day simplicity

This guide applies to:

* bare-metal server deployments
* virtualized or private-cloud environments
* Data Processor (DP), Sensor, and AIO deployment scenarios

> [!TIP]
>
> If you only need to choose a component quickly, start with **[Choose an Installer](https://kvm.xdr.ooo/getting-started/choose-installer.md)**. Use this page when you also need to decide the network model and topology.

## Recommended Configuration by Deployment Environment

| Deployment environment | Target component | Recommended installer | Network mode | SPAN / cluster interface mode | Recommended use case |
| - | - | - | - | - | - |
| Bare metal (3+ servers) | Data Processor (cluster) | Data Processor Installer | NAT | SR-IOV | Large production DP clusters requiring maximum inter-node performance |
| Bare metal (2 servers, with switch) | Data Processor (cluster) | Data Processor Installer | NAT | SR-IOV | High-speed two-node cluster designed for future expansion |
| Bare metal (2 servers, direct connection) | Data Processor (cluster) | Data Processor Installer | NAT | Bridge | Switchless topology, Master + Worker / Warm Standby |
| Bare metal (single server) | Sensor | Modular Sensor Installer | NAT or Bridge | PCI Passthrough | High-performance packet capture using maximum hardware resources |
| Bare metal (single server) | AIO + Sensor | AIO & Sensor Installer | NAT | PCI Passthrough (Sensor) | Compact deployment when hardware is limited |
| Virtualized / private cloud | Data Processor | Data Processor Installer | NAT | Bridge | DP deployment on virtual networking where SR-IOV is unavailable |
| Virtualized / private cloud | Sensor | Modular Sensor Installer | NAT or Bridge | Bridge | Environments where PCI passthrough is restricted |
| Virtualized / private cloud | AIO + Sensor | AIO & Sensor Installer | NAT | PCI Passthrough (Sensor) | Only where the virtualization platform provides physical PCI passthrough |
| Security-isolated Sensor deployment | Sensor only | Modular Sensor Installer | Bridge | PCI Passthrough or Bridge | Strict separation between host and Sensor networking |

## Detailed Deployment Decision Criteria

## 1. Bare-Metal Server Deployment

### 1.1 Data Processor Deployment

#### Three or more physical servers (cluster deployment)

When deploying Data Processors across three or more physical servers, install each server individually according to the **Data Processor Installer guide**.

Recommended approach:

* configure all servers as a DP cluster
* use **Configuration → Cluster Interface Mode**
* set Cluster Interface Mode to **SR-IOV**

#### Why SR-IOV is recommended

* each DP node communicates directly through the physical NIC
* cluster traffic bypasses the virtual-switch layer
* inter-node latency is minimized
* provides the highest practical cluster performance

This deployment model is recommended for production-scale DP clusters.

#### Two-node server cluster

There are two recommended approaches depending on the network design.

##### When a 10GbE switch is available

* set Cluster Interface Mode to **SR-IOV**
* connect both servers to the switch

This configuration provides:

* high throughput
* a topology that can be expanded later

##### When no switch is available (direct connection)

* set Cluster Interface Mode to **Bridge**
* directly connect the two servers using high-speed NICs

This is especially useful when:

* one node acts as the Master
* the second node acts as a Worker or Warm Standby
* a simple switchless topology is required

Bridge mode allows the two servers to communicate directly at Layer 2 without additional infrastructure.

### 1.2 Sensor Deployment on Bare Metal

When deploying a Sensor on a bare-metal server:

* follow the **Modular Sensor Installer guide**
* deploy the Sensor directly on physical hardware to maximize available resources
* attach SPAN NICs using **PCI Passthrough**
  * this is the default and recommended method

#### Key characteristics

* each SPAN NIC is passed directly to the Sensor
* no virtual-switch overhead is introduced
* maximum packet capture and processing performance is available

Multiple SPAN NICs can be attached when:

* the NICs support PCI passthrough
* sufficient hardware resources are available

This deployment model is recommended for high-throughput and high-fidelity traffic capture environments.

## 2. Deploying AIO and Sensor on a Single Server

When hardware resources are limited, AIO and Sensor can be deployed together on one physical server.

Recommended procedure:

* follow the **AIO & Sensor Installer guide**
* deploy both components on the same host

### Important performance considerations

The following configuration is technically possible:

* allocating more vCPUs than are available on NUMA node 0
* skipping CPU pinning
* allowing AIO to use CPUs across multiple NUMA nodes

However, this is not recommended because:

* memory access crosses NUMA boundaries
* latency increases
* overall system performance can degrade

### Recommendation

* keep AIO CPU allocation within a single NUMA node
* use CPU pinning whenever possible
* use multi-NUMA allocation only as a last resort

## 3. Deployment in Virtualized or Private-Cloud Environments

In private-cloud or virtualized environments, direct access to physical hardware is commonly restricted.

### 3.1 Data Processor Deployment

When deploying a Data Processor in a virtualized environment:

* follow the **Data Processor Installer guide**
* set Cluster Interface Mode to **Bridge**

#### Why Bridge mode is required

* physical NIC passthrough is often unavailable
* SR-IOV may be restricted or unsupported
* Bridge mode allows DP nodes to communicate over the virtual network

#### Example architecture

* deploy DL Master on one KVM host
* deploy DA Master on another KVM host
* connect the two nodes using an L2 bridge

### 3.2 Sensor Deployment in a Virtualized Environment

For Sensor deployment:

* follow the **Modular Sensor Installer guide**
* configure SPAN NICs in **Bridge mode**

This approach:

* trades some absolute performance for flexibility
* works reliably where PCI passthrough is unavailable
* fits private-cloud, test, and regulated environments

### 3.3 AIO + Sensor Deployment

The standard **AIO & Sensor Installer** Auto Execute workflow deploys both AIO and Sensor.

* management networking uses **NAT mode**
* Sensor SPAN attachment uses **PCI Passthrough**
* therefore this path may not be appropriate for private clouds that do not expose physical PCI passthrough

If you need AIO only, do not simply run the complete Auto Execute workflow. First verify that an AIO-only design is supported for the target OpenXDR release and operational architecture.

## 4. Sensor-Only Deployment Options

### Network separation for security or operations

Some environments require the Sensor VM network to be separated from the KVM host network for:

* security isolation
* day-to-day visibility
* management-policy compliance

In that case:

* follow the **Modular Sensor Installer guide**
* set Sensor Network Mode to **Bridge**

This allows:

* the Sensor VM to use a dedicated physical interface
* the KVM host to keep a separate management network
* clear separation between management traffic and Sensor traffic

> [!NOTE]
>
> The default Sensor network mode is NAT.

## 5. Network Terminology

This section explains the primary network terms used throughout the installer and deployment guides.

### Bridge Mode (Sensor)

Bridge mode connects a virtual machine directly to a physical or virtual network at Layer 2.

In simple terms:

* the VM behaves like a physical server on the same network
* it has its own MAC address
* traffic flows without address translation

#### When to use it

* high-performance networking
* clear network separation
* direct server-to-server communication

### NAT Mode (Data Processor, AIO, Sensor)

NAT (Network Address Translation) mode places the VM behind the KVM host.

In simple terms:

* the VM uses an internal private IP address
* the host acts as the gateway
* external systems see the host IP address

#### When to use it

* simple deployment environments
* environments with limited IP address resources

#### Trade-offs

* simpler configuration
* additional access and management considerations

### PCI Passthrough (Sensor)

PCI passthrough assigns a physical NIC directly to a virtual machine.

In simple terms:

* the VM controls the NIC directly, similar to bare metal
* no virtual switch or host network stack is in the traffic path
* near-native performance is available

#### When to use it

* high-throughput Sensor deployments
* SPAN or mirrored-traffic collection
* bare-metal or dedicated-hardware environments

### SR-IOV (Data Processor)

SR-IOV (Single Root I/O Virtualization) allows one physical NIC to be divided into multiple virtual NIC functions.

In simple terms:

* one physical NIC is divided into multiple lightweight virtual interfaces
* each virtual interface can be assigned to a VM
* performance is higher than Bridge mode, but operational complexity is also higher

#### When to use it

* Data Processor cluster interfaces
* high-performance multi-node cluster communication
* environments where the hardware and BIOS support SR-IOV


This documentation is built and hosted on [Mintlify](https://mintlify.com), a developer documentation platform.